DAIKIN PRODUCTS

 

SPLIT TYPES

............................................................

Normal Split

............................................................

G-H Series

............................................................

L Series

............................................................

Inverter Split

............................................................

FTKS (410-A Gas)

............................................................

FTKE / FTKD (R-22 Gas)

............................................................

Ceiling Mounted

............................................................

Normal Cassette

............................................................

FHC18NUV1/ FHC21NUV1

............................................................

FHC26NUV1/ FHC30NUV1

............................................................

FHC36NUV1/ FHC42NUV1/FHC48NUV1

............................................................

DUCTABLE TYPES

............................................................

Low Static Pressure Type

............................................................

Middle Pressure Type

............................................................

High Static Pressure Type

............................................................

VRV III

............................................................

Indoor Unit

............................................................

Wall Mounted

............................................................

Wall Mounted - Type

............................................................

Wall Mounted - (Cooling Only)

............................................................

Wall Mounted - (L Series)

............................................................

Wall Mounted - (G-H Series)

............................................................

CEILING MOUNTED TYPES

............................................................

Multi Flow

............................................................

Round Flow

............................................................

Corner Type

............................................................

Double Flow Type

............................................................

Ceiling Suspended Cassette Type

............................................................

Ceiling Suspended Type

............................................................

Ceiling Suspended Type-FH50

............................................................

Ceiling Suspended Cassette

............................................................

Floor / Ceiling Suspended dual Type

............................................................

Floor Standing Type Concealed Floor Standing Type

............................................................

Slim Ceiling Mounted Duct

............................................................

Duct Type 700mm

............................................................

Duct Type 900 / 1,100mm

............................................................

Ceiling Mounted Duct Type

............................................................

Floor Standing Duct Type

............................................................

Outdoor Units

............................................................

Normal Type (50 Hz)

............................................................

5, 18, 10, 12, 14, 16, 18 HP

.......................................................

20, 22, 24, 26, 28, 30, 32 HP

.......................................................

34, 36, 28, 40, 42, 44 HP

.......................................................

46, 48, 50, 52, 54 HP

............................................................

Daikin >> Wall Mounted

.................................................................................................................................................................................................................................................................................

Wall Mounted Non Inverter Type (Cooling Only)

Features

  • New Flat Panel Design : The simple & stylish flat panel design harmonises with any interior décor.
  • Power-Air Flow Dual Flaps : To regulate the outlet aperture to an optimum shape so that cool air slides off to reach the farthest corners of the room.
  • Air-Purifying Filter : Air-Purifying filter with Photocatalytic deodorizing function is able to trap microscopic particles, decompose odours & deactivate viruses.
  • Controller : Easy-to-use and read LCD wireless remote controller.
  • Auto Fan Speed : The microprocessor automatically controls the fan speed to most efficiently adjust the actual room temperature to the set temperature.
  • Self Diagnosis Function : Malfunction codes are shown on the digital display panel of wireless remote controller for the fast & easy maintenance.
  • Auto Restart : Memorization of operating conditions on power failure.
  • On/Off Timer : This function allows a 12-hour timer to be set at the push of a single button.
  • Night Set Mode : To provide comfortable sleep by preventing any sudden change in room temperature.
  • Program “Dry” Mode : For reducing level of humidity while maintaining room temperature.
  • Long Piping Length : Piping length between indoor & outdoor unit can go upto 30 Meters which is useful for easy & flexible Installation.
  • Durability : Heat exchange fins of outdoor unit is provided with anti-corrosion treatment to achieve increased durability.

Wall Mounted Non Inverter G Series (Cooling Only)

Features

  • New Flat Panel Design : The simple & stylish flat panel design harmonises with any interior décor.
  • High Energy Saving : The COP is as high as 3.38.
  • Power-Air Flow dual flaps : To regulate the outlet aperture to an optimum shape so that cool air slides off to reach the farthest corners of the room.
  • Air-Purifying Filter : Air-Purifying filter with Photocatalytic deodorizing function is able to trap microscopic particles, decompose odours & deactivate viruses.
  • Controller : Easy-to-use and read LCD wireless remote controller.
  • Auto fan speed : The microprocessor automatically controls the fan speed to most efficiently adjust the actual room temperature to the set temperature.
  • Self diagnosis function : Malfunction codes are shown on the digital display panel of wireless remote controller for the fast & easy maintenance.
  • Auto Restart : Memorization of operating conditions on power failure.
  • On/Off Timer : This function allows a 12-hour timer to be set at the push of a single button.
  • Night set mode : To provide comfortable sleep by preventing any sudden change in room temperature.
  • Program “dry” mode : For reducing level of humidity while maintaining room temperature.
  • Long piping Length : Piping length between indoor & outdoor unit can go upto 30 Meters which is useful for easy & flexible Installation.
  • Durability : Heat exchange fins of outdoor unit is provided with anti-corrosion treatment to achieve increased durability.
     

Wall Mounted Non Inverter Type (Heat Pumps)

Features

  • Power-Air Flow Dual Flaps : To regulate the outlet aperture to an optimum shape so that cool air slides off to reach the farthest corners of the room.
  • Air-Purifying Filter : Air-Purifying filter with deodorising function is able to trap microscopic particles, decompose odours & deactivate viruses
  • Controller :Easy-to-use and read LCD wireless remote controller.
  • Auto Fan Speed : The microprocessor automatically controls the fan speed to most efficiently adjust the actual room temperature to the set temperature.
  • Hot Start : Uncomfortable cold air is avoided when heating operation starts.
  • Self Diagnosis Function : Malfunction codes are shown on the digital display panel of wireless remote controller for the fast & easy maintenance.
  • Auto Restart : Memorization of operating conditions on power failure.
  • On/Off Timer : This function allows a 12-hour timer to be set at the push of a single button.
  • Night Set Mode : To provide comfortable sleep by preventing any sudden change in room temperature.
  • Program “Dry” Mode : For reducing level of humidity while maintaining room temperature.
  • Long Piping Length : Piping length between indoor & outdoor unit can go upto 30 Meters which is useful for easy & flexible Installation.
  • Durability : Heat exchange fins of outdoor unit is provided with anti-corrosion treatment to achieve increased durability.

Wall Mounted InverterType (Cooling Only/ Heat Pump)

Features

  • New Flat Panel Design : The simple & stylish flat panel design harmonizes with any interior décor.
  • Power-Air Flow Dual Flaps : To regulate the outlet aperture to an optimum shape so that cool air slides off to reach the farthest corners of the room. The flaps can direct warm air straight down to the floor during heating operation.
  • Energy Savings : The unit is equipped with a Reluctance DC compressor, Which controls power used in accordance with load variation which leads to industry leading COP as high as 4.17.
  • Controller : Easy-to-use and read LCD wireless remote controller.
  • Intelligent Eye : Intelligent eye prevents energy wastage by using its infrared sensor to detect human movement in a room.
  • Econo Mode : This function limits both the maximum running current & maximum power consumption to 70% of those during normal operation.
  • Air-Purifying Filter : Air-Purifying filter with Photocatalytic deodorizing function is able to trap microscopic particles, decompose odours & deactivate viruses.
  • Auto Fan Speed : The microprocessor automatically controls the fan speed to most efficiently adjust the actual room temperature to the set temperature.
  • Self Diagnosis Function : Malfunction codes are shown on the digital display panel of wireless remote controller for the fast & easy maintenance.
  • Auto Restart : Memorization of operating conditions on power failure.
  • On/Off Timer : This function allows a 12-hour timer to be set at the push of a single button.
  • Night Set Mode : To provide comfortable sleep by preventing any sudden change in room temperature.
  • Program “Dry” Mode : For reducing level of humidity while maintaining room temperature.
  • Hot Start : Uncomfortable cold air is avoided when heating operation starts ( Available only with heat pump models)
  • Long Piping Length : Piping length between indoor & outdoor unit can go upto 30 Meters which is useful for easy & flexible Installation.
  • Durability : Heat exchange fins of outdoor unit is provided with anti-corrosion treatment to achieve increased durability

 

Home